Network switch – GWNET11

Network switch – GWNET11 connects up to four temperature lines. The connection is made with a signal cable according to a special specification.

A maximum of four GWNET11 can be connected in series per input on a Network controller – GWAB11. The connection between is made with signal cable according to special specification.

ATEX and IECEx approved.

U – Nominal voltage: 5 V
I – Nominal current: 20 mA
P – Nominal power: 100 mW
U – Maximum voltage that can be applied to any terminal without invalidating safety: 8.0 V
I – Maximum current that can be applied to any terminal without invalidating safety: 300 mA
P – Maximum power that can be applied to any terminal without invalidating safety: 500 mW
C – Maximum unprotected internal capacitance: 150 nF
IP-code: IP66
Maximum surface temperature: 85°C
Operating temperature: -20°C – +50°C
Size: L=125 mm, W=80 mm, H=57 mm
Certification: IECEx: GB/EXV/QAR19.0001/00 ATEX: ExVeritas 19PQAN0088
Marking: IECEx: Ex tb [ia] IIIC T85°C ATEX: II (1D) 2D Ex tb [ia] IIIC T85°C
  • Network controller – GWAB11
  • Temperature line – GWSL1100
  • Temperature line – GWSL2100
  • Interface – Web or Grain App

Do you want to know more?

Please fill out the form and we will contact you as soon as possible.

Name